Vista VIP Kit2 VK2-ENCODER Manual do Utilizador Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 11
VK2-2MPBX User manual V1.2
12
Please take steps as follows:
1.
Power off
2.
Press and hold the RESET button
3.
Supply the camera with power
4.
Hold the RESET button for 15 seconds
ALARM connection: Connect one or two physical alarm input signal into the device and one
alarm output signal that can be used to control an external alarm circuit.
BNC connector: Connect BNC cable for composite video output.
INSTALLATION TOP STAND connector: 0.25 Inch (0.64cm) UNC-20 screw, top of camera
housing.
INSTALLATION BOTTOM STAND connector: 0.25 Inch (0.64cm) UNC-20 screw, bottom
of camera housing.
FOCUS ADJUSTING / FIXING screw: Tighten this screw after focus the lens of a camera.
AUTO IRIS LENS connector: Connect the DC auto iris lens 4-pin connector into this
connector to control the amount of light allowed through the lens.
CS MOUNT LENS: connection: Attach the CS type lens.
RS485 connection: Connect RS485 compatible device for PTZ control.
Vista de página 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 103 104

Comentários a estes Manuais

Sem comentários